Pressure Transducers

Pressure Transducers

  • Pressure transducers convert liquid or gas pressures into electric quantities. According to measuring purposes, they are connected to various instruments for monitoring, recording and controlling pressures.
  • They have highly precise dedicated self-temperature compensated strain gauges incorporated as pressure detecting elements and feature a hermetically-sealed structure with inert gas filled in, ensuring superior linearity, thermal characteristics and waterproofness.

MOQ: 1 EA

Contact Information:
Tel:(02)2708-1730 #216   Mr. Wayne Wei

SKU: Pressure Transducers Categories: ,
Picture Type Description Rated Capacity
PGM-G PGM-G series pressure transducers come with the cable in a conduit pipe for back-pressure compensation. Thus, they are easy to handle and enable highly accurate and stable measurement of low pressure. 20~100kPa
  PG-U  Highly accurate and reliable PG-U series pressure transducers are hermetically sealed with inert gas filled in to enable a long-term stable measurement. 200kpa~50MPa
  PGM-H PGM-H series pressure transducers are suitable for pressure measurement in limited space. Because of a diaphragm at the end, it ensures excellent response and dynamic characteristics. 500kPa~50MPa
PGL-A PGL-A series pressure transducers are suitable for pressure measurement in limited space. The semi-flush diaphragm at the top end ensures excellent response and dynamic characteristics. There are 2 types: A type with removable cable and B type with integrated cable. 1~50MPa
PGM-E PGM-E series pressure transducers are extremely effective for pressure measurement in limited space. A flush diaphragm ensures excellent response and dynamic characteristics. Since the pressure sensing part directly contacts the measuring object, they are applicable to highly viscous medium. 1~50MPa
    PGS-A PGS-A series pressure transducers are designed and manufactured to be especially compact and lightweight. 1MPa~50MPa
PGM-D High frequency response and highly accurate flush diaphragm type with small pressure sensing surface. 5~50MPa
PG-H Available with rated capacities of 100 and 200 MPa, the PG-H series pressure transducers are hermetically sealed with inert gas filled in, enabling long-term stable measurement. 100, 200MPa
PGH-S-SA19 Large-capacity pressure transducer.For large capacity and safe design with just one SUS body without welded part. Removable cable 250, 300MPa
Picture Type Description Rated Capacity
PHB-A PHB-A series is designed for pressure measurement from low to high temperatures. The sensor surface is made by stainless steel diaphragm and inert gas is filled in to increase reliability. 1~50MPa
PHL-A PHL-A series pressure transducers are suitable for pressure measurement in not only limited space under both high and low temperature environments but also highly viscous heated fluids like melt resin, high-temperature gases and LPG/LNG tanks. A semiflush diaphragm at the top not only ensures excellent response and dynamic characteristics. 1~50MPa
PGH-S-100MPSA17 Small Φ20×40 (Including 15 long screw portion) and usable at high temperature (150°C) and large capacity (100 MPa) . 100MPa
PHF-S-S3 Excellent in environmental performance, after removing the connector, enables to install in a limited space by a socket wrench. 2~20MPa
  PHC-B The sensor part is a flush diaphragm detecting pressure directly on a flat surface without pressure medium, thus enabling pressure measurement without missing momentary pressure changes. In addition, the flush diaphragm makes these transducers suitable for measuring not only liquid or gas pressure but also pressure of highly viscous medium. The small-sized design and flexible cable make them easy to use even in limited space. 2~20MPa
Picture Type Description Rated Capacity
PAB-A The PAB-A is a absolute pressure transducer for measuring pressure from absolute zero. 200kPaabs.~2MPaabs.
PHS-B   PHS-B series pressure transducers have the thin-film strain gage and temperature-compensating resistive membrane formed directly on the diaphragm by sputtering and photo-lithography, thereby enabling accurate temperature compensation even at high temperatures. 200kPaabs.~20MPaabs.
PGR-A High temperatures (Up to 100°C) and high-pressure-resistant and highly accurate pressure transducer. 1~20MPa
Picture Type Description Rated Capacity
 

PAG-2KA PAG-2KA series pressure transducers are stable and their sensor part is designed to be highly stable. Also, inert gas is sealed hermetically in sensor part, ensuring excellent reliability and stability for longterm. The built-in amplifier is composed of highly-selected reliable components and be fully tuned to provide high-frequency radio noise resistance. 200kPa
                                  PAV-R/U PAV-R/U pressure transducers have dedicated built-in amplifier and output voltage signals from 0 to 5 V. There is no connection by welding in pressure sensor section. The built-in amplifier adopts unique hybrid IC to reduce numbers of components resulting in increasing reliability. 1~50MPa
                        PAA-R/U PAA-R/U pressure transducers have dedicated built-in amplifier and output current signals from 4 to 20 mA. There is no connection by welding in pressure sensor section. The built-in amplifier adopts unique hybrid IC to reduce numbers of components resulting in increasing reliability. 500kPa~50MPa
 

PVL PVL series pressure transducers detect pressures by strain gage and then amplify these slight voltage signals by a built-in amplifier. The pressure sensor part is simply integrated structure and has high reliability. 500kPa~50MPa
 

PAL PAL series pressure transducers amplify detected slight signals by a built-in amplifier and then transmit amplified signals in current. The pressure sensor part is simply integrated structure and has high reliability. Also, the amplifier is fully tuned. 500kPa~50MPa
Picture Type Description Rated Capacity
PDS-A PDS-A series pressure transducers have diffusional semiconductor strain gages on a silicone diaphragm. PDS-A transducers detect pressures as resistance variation and then convert this variation to electrical signals. These signals are indicated by Kyowa’s signal conditioners. 1~7kPa
PDV-A PDV-A series pressure transducers have diffusional semiconductor strain gages on a silicone diaphragm. PDV-A transducers detect pressures as resistance variation and then amplify this signal by built-in amplifier. 1~7kPa
  PD-A PD-A series pressure transducers allow slight differential pressure to be accurately measured. They are suitable for long-term measurements and measurements requiring high accuracy. 10~200kPa
PDU-A The PDU-A is a stainless steel differential pressure transducer for measuring differential pressure under line pressure of max 30 MPa. It has a built-in variable damping mechanism. 50kPa~2MP
Picture Type Description Rated Capacity
PSS PSS series pressure transducers have a bridge of strain gages inside, achieving ultra-thin compact structure. A thin-film strain gage is directly formed on a diaphragm by sputtering and photo lithography. 20,50,100kPa
PS   The PS-C is a miniature pressure sensor with a strain-gage bridge inside. The cable direction is parallel to the sensor surface. And the PS-D cable direction is at right angle to the sensor surface. 50kPa~7MPa
PSM-AB The PSM-AB is a miniature pressure sensor with a flurocarbon resin cable. It adopts quarter-bridge 3-wire mode and configures a full bridge by a bridge adapter. 100, 200kPa