Load Cell

Load Cell

  • KYOWA load cells can be used in sensing applications ranging from general force measurement in testing or research to measuring and controlling weight (mass) in tanks, hoppers, mills, vehicles, etc.

MOQ: 1 EA

Contact Information:
Tel:(02)2708-1730 #216   Mr. Wayne Wei

SKU: Load Cell Categories: ,
Picrure Type Description Rated Capacity
LMA-A Compact and lightweight LMA-A series load cells are used by just putting or bonding on the measurement point or setting in a hollow. 5N~1kN
      LMB-A Ultra-small and lightweight LMB-A series load cells are used by just putting or bonding on the measurement point or setting in a hollow. 10N~2kN
      LMBT-A Ultra-small and lightweight. For high temperature up to 100°C. Just putting or bonding on the measurement point or setting in a hollow. 50N~2kN
LMR-S-SA2 Compact & lightweight LMR-S-SA2 series load cells are used by just putting or bonding on the measurement point or setting in a hollow. Major applications include measurement of load distribution by using multiple units, load measurement in pipe making mills or where a measuring site or the weight of the load cell itself is limited. 2~20kN
  LMC-A Compact & lightweight load cells are used by just putting or bonding on the measurement point, setting in a hollow, or affixing with a mounting band. Major applications include measurement of load distribution by using multiple units, load measurement in pipe making mills, or where a measuring site or the weight of the load cell itself is limited. 5~50kN
LCN-A Compact & lightweight design facilitates installation into existing facilities. Excellent stability and reliability are ensured by the hermetically-sealed structure with inert gas filled in. Furthermore, the stainless steel (SUS 630) enclosure makes them widely usable as sensors for equipment requiring corrosion resistance. 500N~20kN
      LCX-A-ID This is a compact, lightweight, and thin load cell, easy to incorporate into existing equipment. The case is an all-stainless steel product. Additionally, the cable is connected using a connector, therefore there are no wring problems, and cable replacement is easy. Models with the cable which is resistant to repeated bending (flexible cable) are available. Please attach a suffix of M1Z3K to the model name. 500N~20kN
  LC-E Inert gas is filled in the detector portion, thereby preventing aging deterioration and ensuring a stable and reliable operation. 2, 5MN
LC-V Compact & lightweight design facilitates installation into existing facilities. While nonlinearity of within ±0.05% RO is ensured, the hermetically-sealed structure with inert gas filled in enables highly stable and reliable measurement. 50~200kN
      LCH-F Useable in high humidity. Degree of protection: IP67 (IEC 60529) 100, 200kN
LCV-A LCV-A series is a compact & lightweight load cell developed for large capacity (500 kN and 1 MN). They are easily installed into existing facilities. The hermetically-sealed structure with inert gas filled in ensures stable and reliable performance with 0.1% nonlinearity. Use of BISELCOM gages ensures increased output and improved reliability. 500kN, 1MN
  LCK-A The LCK-A series load cells have excellent accuracy, reliability, stability, and response. They also have a thin design for convenient installation as detection terminals of weighing systems. This thin design makes them suitable for applications such as conveyors, vehicles, cranes, hoppers, and tanks where the space, especially the height, is limited and the detecting part needs to be downsized. 5~200kN
  LC-FH Able to continuously operate at temperatures up to 150°C without any external cooling. 500N~200kN
LUB-B LUB-5KB to 50KB feature a nonlinearity of within ±0.03% RO and LUB-100KB to 2TB feature corrosionresistant stainless steel body and bellows. As load detectors, they enable configuration of accurate and stable weighing systems for conveyors and tanks. 50N~20kN

 

Picrure Type Description Rated Capacity
LVS-A The LVS-A series measures loads in vertical direction to the mounted surface. 50mN~20N
LTS-A The LTS-A series, in horizontal direction. 500mN~20N
LTZ-A Adopt the Roberval’s mechanism to ensure the linearity of within ±0.05% RO 500N~50kN
LT-FH/FL With the mechanical stopper that activates at 500% overload.

LT-FH series enables continuous operation under temperature as high as 150°C with no external cooling. LT-FL series enable operation at ultra-low temperature of -196°C.

500N~50kN
Picrure Type Description Rated Capacity
    LUX-B-ID Compact & lightweight design with a screw-shape load receiving portion facilitates easy installation to equipment. Furthermore, the cable is connected using a connector, therefore there are no wring problems, and cable replacement is easy. Work is also possible if the cable is replaced with one resistant to repeated bending (Flexible cable). ±50N~±20kN
  LUR-A-SA1 Compact & lightweight LUR-A-S1 series are easy to use tension/compression load cells. They are used in various fields ranging from production lines to experiments. ±50N~±2kN
      LU-E The detection portion is hermetically sealed with inert gas filled in to prevent aging deterioration and to ensure reliability and stability for a long period of time. ±500N~±200kN
LUH-F LUH-F series are tension/compression load cells featuring within ±0.02% RO nonlinearity. The hermetically-sealed structure with inert gas filled in ensures stable performance. ±500N~±200kN
    LUK-A The thin structure is suitable for installation where the height is limited. The service life will be extended by using with one-half the rated capacity if repetitive loads are applied continuously. ±5kN~±2MN
  LU-A A straight beam is used as the diaphragm to enable highly accurate measurement of small loads. ±50N~±200N
  LUR-B-SA1 LUR-B-SA1 series load cells are designed to measure loads applied to jacks when lifting up or moving a large machinery or structure in civil engineering and construction fields. These load cells enable the operators to prevent overloads, unbalanced loads, or movement of the center of gravity. ±10Kn~±2MN
Scroll to Top